ROOM AIR CONDITIONERSERVICE MANUALCAUTIONBEFORE SERVICING THE UNIT, READ THE SAFETY PRECAUTIONS IN THIS MANUAL.website: http://www.lgservice.come-mail
—10—2.3.6 POWER CORD1. Disconnect the unit from source of power.2. Remove the front grille. (Refer to Section 2.1.1)3. Remove the cabinet. (Refer to S
2.4.3 CAPILLARY TUBE1. Remove the cabinet.2. Discharge the refrigerant by using a refrigerantrecovery system.3. Remove the air guide upper. (Refer to
—12—Equipment needed: Vacuum pump, charging cylinder, manifold gauge, brazing equipment, pinch-off tool capableof making a vapor proof seal, leak dete
—13—3. INSTALLATION This air conditioner is designed with a button-downchassis so it can be easily installed in a window. 3.1 SELECT THE BEST LOCATION
—14—Installation3.2.2 BEFORE INSTALLATION1. Insert the guide panels into the guides of the air condi-tioner. Fasten the curtains to the unit with scre
3. INSTALL THE AIR CONDITIONER IN THE WINDOWa. Carefully lift the air conditioner and slide it into theopen window. Make sure the bottom guide of the
—16—REMOVAL FROM WINDOWTurn the air conditioner off, disconnect the power cord, remove the L bracket and the screws installed through the top and bot-
—17—4.2 PIPING SYSTEMFollowing is a brief description of the important components and their function in what is called the refrigerationsystem. Refere
—18—4.3 TROUBLESHOOTING GUIDE In general, possible trouble is classified in two kinds. The one is called Starting Failure which is caused by an electr
—19—Fails to Start Improper thermistor setting Loose terminal connection Improper wiring Check of power source. Drop of power voltage. Capacitor check
—2—CONTENTS 1. PREFACE ... 21.1 FEATURES...
—20—Is the Trans output powerAC 115V?Is the Trans output powerabout AC 14V?Is shorted the Trans. output?Is output Voltage of IC01DDC 12V?Is output Vol
—21—Is Temp.setting set lower than Room Temp.-0.5°C?Is the voltage No.11of IC01M 0V?• Exchange IC01M.• Set the Temp. setting to higher Temp.• Wait 3 M
—22—Is the voltage of Batteryabout over 2.3V?•Exchange Receiver Ass'y.Is the connection of CN-DISP2 all right?Is the voltage No.10 of CN-DISP2 on
—23—ROOM AIR CONDITIONER VOLTAGE LIMITS NAME PLATE RATING MINIMUM MAXIMUM 115V ± 10% 103.5V 126.5V COMPLAINT CAUSE REMEDY Fan motor will not run.
—24—COMPLAINT CAUSE REMEDY Fan motor noise. Fan If cracked, out of balance, or partially missing, replace it. Blower If cracked, out of balance,
—25—COMPLAINT CAUSE REMEDY Compressor cycles on Fan motor If not running, determine the cause. Replace if overload required. Condenser air flow Re
—26—LOCATIONNO.123456785. SCHEMATIC DIAGRAM 5.1 CIRCUIT DIAGRAM• MODEL : M5403R, M5203R, M5203L, M6003R, WM-6011, LWJ0611PCG, LWC061JGMK1Q'TY PER
—27—5.2 ELECTRONIC CONTROL DEVICE
—28—5.3 COMPONENTS LOCATION(FOR MAIN P.W.B ASM)5.4 COMPONENTS LOCATION(FOR DISPLAY P.W.B ASM)
—29—6. EXPLODED VIEW135313352390267110152302130410359012W48602135312354210349480352380149980559011346811554030W48602130910264110238310W0CZZ24995026871
1.2 SPECIFICATIONS • NOTE: Specifications are subject to minor change without notice for further improvement. —3—MODELS ITEMS COOLING CAPACITY (BTU/h)
—30—7. SERVICE PARTS LIST LOCATION NODESCRIPTIONREMARKSM5403R M5203R M5203L130410 BASE ASSY, SINGLE 3041A10011E R130910 CABINET ASSY ,SINGLE 3091A1002
—31—M6003R WM-6011 LWJ0611PCGLWC061JGMK1130410 BASE ASSY, SINGLE 3041A10011E 3041A10011E 3041A10011E 3041A10011E R130910 CABINET ASSY, SINGLE 3091A100
P/No.: 3828A20038BFebruary, 2003Printed in Korea
—4—1.5 LOCATIONS OF CONTROLS 1.5.1 CONTROLS Dry FanCoolON/OFF TIMER- STOPPING OPERATION• Everytime you push this button, when the unit is operating,
—5—1.5.2 REMOTE CONTROLLERHow to Insert Batteries1. Remove the cover from the back of theremote controller2. Insert two batteries.• Be sure that the
—6—2. DISASSEMBLY INSTRUCTIONS 2.1 MECHANICAL PARTS 2.1.1 FRONT GRILLE 1. Disconnect the unit from source of power.2. Using a screwdriver, remove the
—7—2.2 AIR HANDLING PARTS 2.2.1 AIR GUIDE UPPER 1. Disconnect the unit from the power source.2. Remove the front grille. (Refer to Section 2.1.1)3.
—8—2.2.3 MOTOR1. Disconnect the unit from the power source.2. Remove the front grille. (Refer to Section 2.1.1)3. Remove the cabinet. (Refer to Sectio
—9—2.3.2 COMPRESSOR 1. Remove the front grille and cabinet. (Refer to Section 2.1.2) 2. Discharge the refrigerant by using a refrigerantrecovery syste